<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهان</PublisherName>
				<JournalTitle>مجله آب و فاضلاب</JournalTitle>
				<Issn>1024-5936</Issn>
				<Volume>19</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2008</Year>
					<Month>06</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Efficiency of Horizontal Roughing Filter (HRF) in Coliform Removal from Aerated Lagoon Effluent</ArticleTitle>
<VernacularTitle>کارایی صافی درشت دانه با جریان افقی (HRF) در کاهش کلیفرم پساب خروجی لاگون هوادهی تصفیه‌خانه فاضلاب شهر قم</VernacularTitle>
			<FirstPage>2</FirstPage>
			<LastPage>9</LastPage>
			<ELocationID EIdType="pii">2173</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>رامین</FirstName>
					<LastName>نبی‌زاده</LastName>
<Affiliation>استادیار گروه مهندسی بهداشت محیط, دانشکده بهداشت و انستیتو تحقیقات بهداشتی, دانشگاه علوم پزشکی تهران</Affiliation>

</Author>
<Author>
					<FirstName>کاظم</FirstName>
					<LastName>ندافی</LastName>
<Affiliation>دانشیار گروه مهندسی بهداشت محیط, دانشکده بهداشت و انستیتو تحقیقات بهداشتی, دانشگاه علوم پزشکی تهران</Affiliation>

</Author>
<Author>
					<FirstName>فروغ</FirstName>
					<LastName>واعظی</LastName>
<Affiliation>دانشیار گروه مهندسی بهداشت محیط, دانشکده بهداشت و انستیتو تحقیقات بهداشتی, دانشگاه علوم پزشکی تهران</Affiliation>

</Author>
<Author>
					<FirstName>محمد</FirstName>
					<LastName>خزایی</LastName>
<Affiliation>کارشناس ارشد گروه مهندسی بهداشت محیط, دانشگاه علوم پزشکی قم</Affiliation>

</Author>
<Author>
					<FirstName>مرتضی</FirstName>
					<LastName>صفدری</LastName>
<Affiliation>کارشناس گروه مهندسی بهداشت محیط، دانشگاه علوم پزشکی قم</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2007</Year>
					<Month>09</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		<Abstract>Horizontal roughing filters (HRF) can properly remove suspended solids and microorganisms from surface waters if they operate at filtration rates below 1.5 m/h. These filters are common raw water pre-treatment before slow sand filters. This study was conducted by installing an HRF pilot system on effluent pumping station city of Qom wastewater treatment plant based on the aerated lagoon process. The pilot was a horizontal cylindrical column consisting of three compartments filled with river gravel of various sizes. Grab samples were simultaneously taken from inlet and outlet of the HRF at three filtration rates: 0.5, 1, and 1.5 m/h. Total and fecal coliforms were tested according to standard methods for water and wastewater tests. Results indicated that filtration rate had a significant effect on the amounts of total and fecal coliforms in HRF effluent. For the HRF steady-state operation, average total coliform removal efficiency for all filtration rates was higher than 87 percent.</Abstract>
			<OtherAbstract Language="FA">صافیهای درشت دانه با جریان افقی در نرخهای فیلتراسیون کمتر از 1/5 متر بر ساعت توانایی قابل قبولی در کاهش جامدات معلق و بار میکربی منابع آب سطحی، بدون استفاده از مواد منعقد کننده دارند و از گزینه‌های مطرح پیش‌تصفیه قبل از صافی شنی کُند محسوب می‌شوند. در محل ایستگاه پمپاژ پساب تصفیه‌خانة فاضلاب شهر قم یک واحد پایلوت صافی درشت دانه با جریان افقی نصب گردید. طراحی این صافی با اقتباس از نمونه‌های مورد استفاده از این نوع در پیش تصفیه آبهای سطحی انجام گرفت. صافی مزبور به صورت استوانه‌ای به شعاع قاعده 0/25 متر و طول 4 متر همراه با سه لایه ساخته شد. عملیات نمونه‌برداری در سه نرخ فیلتراسیون 0/5, 1 و 1/5 متر بر ساعت انجام شد و شامل برداشت همزمان روزانه از ورودی و خروجی صافی به منظور انجام آزمایش‌های تعیین کل کلیفرم و کلیفرم مدفوعی بود. تحلیل آماری آنالیز کوواریانس داده‌های جمع‌آوری شده نشان می‌دهد که نرخ فیلتراسیون دارای تأثیر معنی‌داری بر مقادیر خروجی کل کلیفرم و کلیفرم مدفوعی است. در حالت عملکرد بهینه صافی, میانگین حذف کل کلیفرم‌ها در هر سه نرخ فیلتراسیون بیش از 90 درصد گزارش شد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">کل کلیفرم‌ها</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کلیفرم‌های مدفوعی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تصفیه فاضلاب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">صافی درشت دانه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">لاگون هوادهی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.wwjournal.ir/article_2173_7bc1ec1d9c3426357e69acd5bf320061.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
