مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Removal of Hydrogen Sulfide from the Sour Water of Tabriz Refinery Using Clinoptilolite Zeolite Adsorbentحذف هیدروژن سولفید از آب ترش پالایشگاه تبریز با استفاده از جاذب زئولیت کلینوپتیلولیت11512082410.22093/wwj.2020.228670.3011FAحسن اسماعیل زادهدانشجوی دکترا، گروه علوم و مهندسی محیطزیست، واحد اردبیل، دانشگاه آزاد اسلامی، اردبیل، ایرانابراهیم فتاییدانشیار، گروه علوم و مهندسی محیطزیست، واحد اردبیل، دانشگاه آزاد اسلامی، اردبیل، ایرانحسین سعادتیاستادیار، گروه علوم و مهندسی محیط زیست، واحد اردبیل، دانشگاه آزاد اسلامی، اردبیل، ایرانJournal Article20200426Hydrogen sulfide (H<sub>2</sub>S) is a toxic, odorous, colorless, flammable and acidic gas. The main problems of hydrogen sulfide are the threat to health and safety, and causing corrosion and damage to metal installations. This study was conducted to remove hydrogen sulfide from the sour waters of Tabriz refinery and to recycle large amounts of water as well as to reduce air pollution in the refinery. In this experimental and laboratory study, the effect of pH, adsorbent content, initial concentration of pollutant, contact time and temperature on hydrogen sulfide removal process using clinoptilolite adsorbent was investigated. Thermodynamics, kinetics, and isotherms of adsorption process were studied. The results were used to remove H<sub>2</sub>S from the sour water of Tabriz refinery. The results showed that the optimal values of pH, absorbent value, initial pollutant concentration, contact time and temperature were 3, 1g/100 mL, 50 mg/L, 30 min and 25 <sup>o</sup>C, respectively. The results of thermodynamic studies showed that the adsorption process was exothermic, irreversible and spontaneous. The experimental data were better fitted to the pseudo-second order kinetics model and Freundlich isotherm model. After passing 100 ml of sour water from the fixed bed at 25 <sup>o</sup>C and 45 minutes, the removal efficiency was 96.7%. According to the results of this study, the proposed method due to its simplicity and high efficiency and the clinoptilolite due to its cheapness, abundance, ability to resuscitate and increase efficiency by enhancing the amount of clinoptilolite can be considered as an appropriate method and suitable adsorbent to remove hydrogen sulfide from the sour water of refineries and effluents.<strong>هیدروژن سولفید (H<sub>2</sub>S) گازی سمّی، بد بو، بیرنگ، آتشگیر و دارای خاصیت اسیدی است. مشکلات عمده هیدروژن سولفید، تهدید سلامتی و ایمنی، ایجاد خوردگی و آسیب به تأسیسات فلزی است. این پژوهش بهمنظور حذف هیدروژن سولفید از آبهای ترش پالایشگاه تبریز و بازیافت مقدار بسیار زیادی آب و همچنین کاهش آلودگی هوای پالایشگاه انجام شد. در این پژوهش تجربی و آزمایشگاهی با استفاده از روش جذب سطحی، تأثیر پارامترهای pH، مقدار جاذب، غلظت اولیه آلاینده، زمان تماس و دما بر فرایند حذف هیدروژن سولفید با استفاده از جاذب کلینوپتیلولیت بررسی شد و ترمودینامیک، سینتیک و ایزوترم فرایند جذب بررسی شد. از نتایج بهدست آمده برای حذف H<sub>2</sub>S از آب ترش پالایشگاه تبریز استفاده شد. نتایج نشان داد مقدار بهینه pH، مقدار جاذب، غلظت اولیه آلاینده، زمان تماس و دما بهترتیب برابر با 3، 1 گرم در 100میلیلیتر محلول، 50 میلیگرم در لیتر، 30 دقیقه و 25 درجه سلسیوس بود. نتایج حاصل از بررسی ترمودینامیکی نشان داد که فرایند جذب گرماده، برگشتناپذیر و خودبهخودی بود. نتایج تجربی نشان داد که سینتیک جذب با مدل شبهمرتبه دوم و ایزوترم جذب با مدل فروندولیچ برازش بهتری داشت. کارایی حذف هیدروژن سولفید بعد از عبور 100 میلیلیتر آب ترش از بستر ثابت در شرایط دمایی 25 درجه سلسیوس و در مدت 45 دقیقه برابر با 7/96 درصد بود. مطابق نتایج این پژوهش روش بهکار برده شده، بهدلیل سادگی عمل و کارایی زیاد و جاذب انتخاب شده بهدلیل ارزانی، فراوانی، قابلیت احیا و افزایش کارایی با افزایش مقدار جاذب، میتوانند بهعنوان روش و جاذب مناسب برای حذف هیدروژن سولفید از پسابها و آب ترش پالایشگاهها استفاده شوند.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Evaluation of Hydraulic Performance of a Type of Vertical Axis Water Microturbine for Use in Medium Pressure Water Supply Networkارزیابی عملکرد هیدرولیکی یک نوع میکروتوربین آبی عمود محور برای استفاده در شبکه آبرسانی فشار متوسط162612648810.22093/wwj.2020.199431.2914FAحسین امجدیدانشآموخته کارشناسی ارشد، مهندسی مکانیک بیوسیستم، انرژیهای تجدیدپذیر،
پردیس ابوریحان دانشگاه تهران، تهران، ایرانجابر سلطانیاستادیار، گروه مهندسی آبیاری، سازههای آبی، پردیس ابوریحان دانشگاه تهران، تهران، ایرانمرتضی خشهچیاستادیار، گروه فنی کشاورزی، مهندسی مکانیک بیوسیستم، پردیس ابوریحان دانشگاه تهران، تهران، ایران0000-0001-8636-4718امیر حسین احمدی حاجیدانشآموخته کارشناسی ارشد، گروه مهندسی آبیاری، سازههای آبی، پردیس ابوریحان دانشگاه تهران، تهران، ایرانJournal Article20190827One of the oldest methods of producing electrical energy is the use of latent energy in running water, which uses a water turbine to achieve this. It is one of the most important sources of renewable energy and has attracted the attention of many researchers in recent years. In this study, laboratory evaluation of hydraulic performance of a type of water microturbine to convert excess pressure in medium pressure water supply networks into electrical energy usable for sensors or equipment such as flow meters, pressure meters, leak detectors, etc., used to manage energy consumption and intelligent water supply networks is investigated. For this purpose, in three different scenarios, the effect of parameters such as flow rate, pressure and different angles of the guide vane on the microturbine performance and pressure drop was investigated. The results showed that the highest microturbine output power (59.01 watts) and pressure drop rate (9.71 meters H<sub>2</sub>O) were obtained when the inlet discharge was 42.61 m<sup>3</sup>/hr and the opening guide vane was 20 degrees. It also has the lowest output power (0.8 watts) and pressure drop rate (4.65 meters H<sub>2</sub>O) for a flow rate of 46 m<sup>3</sup>/hr without the guide vane. The coefficient of determination (R<sup>2</sup>) for the equations of microturbine output power and pressure drop was calculated to be 0.92 and 0.99, respectively.<strong>یکی از قدیمیترین روشهای تولید انرژی الکتریکی، استفاده از انرژی نهفته در آب جاری است که برای دستیابی به این هدف از یک توربین آبی استفاده میشود. این انرژی یکی از مهمترین منابع انرژی تجدیدپذیر محسوب میشود که در سالهای اخیر توجه بسیاری از پژوهشگران را بهخود جلب کرده است. در این پژوهش به ارزیابی آزمایشگاهی عملکرد هیدرولیکی یک نوع میکروتوربین آبی برای تبدیل فشار اضافی موجود در شبکههای آبرسانی فشار متوسط به انرژی الکتریکی قابلاستفاده برای حسگرها و یا تجهیزاتی مانند فلومترها، فشارسنجها و سیستمهای نشتیاب که بهمنظور مدیریت مصرف انرژی و هوشمندسازی شبکههای آبرسانی استفاده میشوند، پرداخته شد. برای این منظور طی سه سناریوی مختلف، تأثیر پارامترهایی مانند دبی، فشار و زوایای مختلف صفحه هدایتکننده جریان بر روی عملکرد میکروتوربین و میزان افت فشار بررسی شد. نتایج نشان داد، بیشترین توان خروجی میکروتوربین 01/59 وات و میزان افت فشار 71/9 متر آب مربوط به زمانی است که دبی ورودی 61/42 مترمکعب بر ساعت است و بازشدگی صفحه هدایتکننده جریان 20 درجه است. کمترین میزان توان خروجی 8/0 وات و افت فشار 65/4 متر آب نیز برای حالتی است که دبی ورودی برابر با 46 مترمکعب بر ساعت و از صفحه هدایتکننده جریان استفاده نشده است. مقدار ضریب تعیین (</strong><strong>R<sup>2</sup></strong><strong>) برای معادلات توان خروجی میکروتوربین و میزان افت فشار بهترتیب به میزان 92/0 و 99/0 محاسبه شد.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Ranking of Cultural Methods for Optimal Domestic Water Consumption in Metropolitan Cities Using the Integrated Grey-AHP and Grey-TOPSIS Modelرتبهبندی روشهای فرهنگسازی مصرف بهینه خانگی آب در کلانشهرها با استفاده از مدل تلفیقی Grey-AHP و Grey-TOPSIS274012647010.22093/wwj.2020.222682.2998FAمحسن کدخداییدانشآموخته کارشناسی ارشد، گروه مهندسی عمران، دانشکده مهندسی، دانشگاه فردوسی مشهد، مشهد، ایرانمحمدرضا جعفرزادهاستاد، گروه مهندسی عمران، دانشکده مهندسی، پژوهشکده آب و محیطزیست،
دانشگاه فردوسی مشهد، مشهد، ایرانعلی عباسیاستادیار، گروه مهندسی عمران، دانشکده مهندسی، دانشگاه فردوسی مشهد، مشهد، ایرانJournal Article20200307The scarcity of water resources and the increasing demand for household water, as a result of urban population growth, have made it difficult for the citizens to supply the water they need in metropolises. Therefore, it is necessary to reduce the amount of domestic water consumption in metropolitan areas using management and consumption control strategies. One of the most effective methods to modify the pattern of water consumption is changing the consumers’ behavior for efficient water use. (Social) Media advertising, establishing training programs for consumers (citizens), implementing effective training programs in schools, spreading educational brochures among water consumers and and billboard advertising are the most practical approaches to promote water saving behavior in metropolises. The aim of this study is to rank the mentioned methods in changing the water consumption behavior of the citizens. Evaluation and ranking of these methods are carried out applying the integrated method of Grey Analytic Hierarchy Process (Grey-AHP) and Grey-TOPSIS. In this study, Mashhad metropolis was selected as a case study. The results show that (social) media advertising and and billboard advertising are the most influential approaches for promoting the effective consumption of water in Mashhad. Distributing educational brochures, educational materials in schools, and establishing training programs for citizens are ranked second to fourth, respectively. Practical approaches to promote water saving behavior, which are easier to apply, are more appropriate and have a greater influence on reducing water consumption.<strong>محدود بودن منابع آب از یک سو و افزایش تقاضای مصارف خانگی آب در اثر رشد جمعیت شهری از سوی دیگر، تأمین آب موردنیاز شهروندان در کلانشهرها را با مشکل مواجه کرده است. بنابراین ضروری است با استفاده از راهکارهای مدیریت و کنترل مصرف، میزان مصارف خانگی آب در کلانشهرها کاهش داده شود. با درک این ضرورت، اصلاح الگوی مصرف آب در کلانشهرها میتواند بهعنوان یکی از مؤثرترین راهکارهای عملیاتی، مدنظر قرار گیرد. نخستین گام در این راستا، فرهنگسازی برای مصرف بهینه آب در میان شهروندان و مشترکان آب شهری است. از جمله کاربردیترین شیوههای فرهنگسازی مصرف بهینه آب در کلانشهرها میتوان به تبلیغات رسانهای، برگزاری دورههای آموزشی برای شهروندان، برگزاری دورههای آموزشی در مدارس، توزیع بروشورهای آموزشی در بین مشترکان آب شهری و استفاده از بیلبوردهای تبلیغاتی اشاره کرد. هدف از انجام این پژوهش، رتبهبندی شیوههای ذکر شده برای تغییر رفتار مصرف آب شهروندان است. ارزیابی و رتبهبندی انجام شده در این پژوهش با استفاده از روش تلفیقی تحلیل سلسله مراتبی خاکستری (</strong><strong>Grey-AHP</strong><strong>) و روش تاپسیس خاکستری (</strong><strong>Grey-TOPSIS</strong><strong>) انجام شد. در این پژوهش، کلانشهر مشهد بهعنوان مطالعه موردی پژوهش انتخاب شد. بر اساس نتایج بهدست آمده، تبلیغات رسانهای و استفاده از بیلبوردهای تبلیغاتی مشترکاً بهعنوان مناسبترین شیوههای فرهنگسازی مصرف بهینه آب در شهر مشهد شناخته شدند. شیوههای توزیع بروشورهای آموزشی، آموزش در مدارس و برگزاری دورههای آموزشی برای شهروندان نیز بهترتیب در رتبههای دوم تا چهارم قرار گرفتند. شیوههای فرهنگسازی مصرف بهینه آب که استفاده از آنها سهولت بیشتری دارد، مناسبتر بوده و تأثیر بیشتری بر کاهش مصرف آب دارند.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Removal of Heavy Metals from Water and Wastewater Using Nanoporous SBA-15 Adsorbentsحذف فلزات سنگین از آب و پساب با استفاده از جاذبهای نانومتخلخل SBA-15415212653210.22093/wwj.2020.219665.2989FAمریم فتاحیکارشناس ارشد، گروه شیمی، دانشکده علوم، واحد یادگار امام خمینی (ره) شهر ری، دانشگاه آزاد اسلامی، تهران، ایرانلیلا حاجی آقابابائیدانشیار، گروه شیمی، دانشکده علوم، واحد یادگار امام خمینی (ره) شهر ری، دانشگاه آزاد اسلامی، تهران، ایران0000-0001-8981-8447علیرضا بدیعیاستاد، گروه شیمی، دانشکده علوم، دانشگاه تهران، تهران، ایرانمحمد رضا گنجعلیاستاد، مرکز عالی الکتروشیمی، گروه شیمی، دانشکده علوم، دانشگاه تهران، تهران، ایرانقدسی محمدی زیارانیاستاد، دانشکده شیمی، دانشگاه الزهرا، تهران، ایرانJournal Article20200212Nowadays, provision of sanitary water is one of the main concerns of the world society, and heavy metals are one of the most important pollutants in water resources. Heavy metals, including copper, can enter the food chain and the body of living organisms and can affect humans through toxic and carcinogenic effects. Therefore, in this study, nanoporous SBA-15 functionalized with di and tetra carboxylic acid was synthesized and used for remove copper ions from aqueous solutions. The adsorbents were characterized by scanning electron microscopy, N<sub>2</sub> adsorption-desorption measurements and infrared spectroscopy for investigation of porosity and functional groups of mesoporous silica. Flame atomic absorption spectroscopy was used for determination of ions. Effective parameters on removal process including amount of adsorbent, contact time, pH of solution and presence of other metal ions in the medium, were evaluated and optimized. The best removal efficiency with di and tetra carboxylic acid functionalized SBA-15 was obtained at pH>5 with 10 mg of adsorbent in the stirring time of 15 minutes. The recovery of copper from adsorbents was done with 20 ml solution of nitric acid (3 mol/L). Langmuir and Freundlich adsorption isotherms were evaluated for both adsorbents. According to the Langmuier model, the maximum adsorption capacity of 232.56 and 93.46 mg of copper per gram of adsorbent and correlation coefficients (R<sup>2</sup>) of 0.857 and 0.9688 for di and tetra carboxylic acid functionalized SBA-15 were obtained, respectively. But, the correlation coefficients (R<sup>2</sup>) obtained from the fitting of the data using the Friendlich isotherm were 0.991 and 0.972 for di and tetra carboxylic acid functionalized SBA-15 silicas, respectively, which indicates that this model is suitable to explaining the behavior of copper adsorption on both adsorbents. Finally, the removal of copper from real wastewater samples was performed. The results indicate that nanoporous SBA-15 silicas functionalized with di and tetra carboxylic acid are desirable adsorbents for copper ions removal.<strong>امروزه تأمین آب بهداشتی یکی از دغدغههای اساسی جامعه جهانی است و فلزات سنگین یکی از مهمترین آلایندههای منابع آب هستند. فلزات سنگین از جمله مس میتوانند به زنجیره غذایی و بدن موجودات زنده وارد شوند و انسان را تحت تأثیر عوارض سمیّت و سرطانزایی قرار دهند. بنابراین در این پژوهش، </strong><strong>SBA-15</strong><strong> نانومتخلخل عاملدار شده با گروههای دی و تترا کربوکسیلیک اسید سنتز شدند و برای حذف یونهای مس از محلولهای آبی استفاده شدند. جاذبها با روشهای تصویر میکروسکوپ الکترونی روبشی، جذب- واجذب گاز نیتروژن و طیفسنجی </strong><strong>FTIR</strong><strong> برای بررسی تخلخل و گروههای عاملی سیلیکای مزوپوری شناسایی شدند. اندازهگیری غلظت یونها با روش طیفسنجی جذب اتمی شعلهای انجام شد. پارامترهای مؤثر بر فرایند حذف چون مقدار جاذب، زمان تماس، </strong><strong>pH</strong><strong> محلول و حضور سایر یونهای فلزی در محیط ارزیابی و بهینه شد. بهترین کارایی حذف بهوسیله جاذبهای </strong><strong>SBA-15</strong><strong> عاملدار شده با گروههای دی و تترا کربوکسیلیک اسید، در 5</strong><strong>pH></strong><strong> و با مقدار 10 میلیگرم جاذب بعد از 15 دقیقه بهدست آمد. بازیابی مس از جاذبها با 20 میلیلیتر اسید نیتریک 3 مولار انجام شد. دادههای جذب با استفاده از ایزوترمهای لانگمیر و فروندلیچ برای هر دو جاذب تجزیهوتحلیل شدند. بر اساس مدل لانگمیر، ماکسیمم ظرفیت جذب 56/232 و 46/93 میلیگرم مس بهازای هر گرم جاذب و ضرایب همبستگی برابر 857/0 و 968/0 بهترتیب برای </strong><strong>SBA-15</strong><strong> عاملدار شده با گروههای دی و تترا کربوکسیلیک اسید بهدست آمد. اما ضرایب همبستگی بهدست آمده از برازش دادهها با استفاده از ایزوترم فروندلیچ برای </strong><strong>SBA-15</strong><strong> عاملدار شده با گروههای دی و تترا کربوکسیلیک اسید بهترتیب برابر 991/0 و 972/0 بود که نشاندهنده مطلوب بودن این مدل در تشریح رفتار جذب مس بر روی هر دو جاذب است. در نهایت، حذف مس از نمونههای پساب واقعی انجام شد. نتایج نشان داد که هر دو نانومتخلخل </strong><strong>SBA-15</strong><strong> عاملدار شده با گروههای دی و تترا کربوکسیلیک اسید، جاذبهای مناسبی برای حذف یونهای مس است.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Investigation of Adsorption Isotherm of Modified Graphene Oxide by Organic Dendrimers to Remove Butachlor Pecticides from Aqueous Solutionبررسی ایزوترم جذب گرافن اکساید اصلاح شده توسط دندریمرهای آلی برای حذف سم بوتاکلر از محیط آبی536812787610.22093/wwj.2020.206398.2941FAسها نزهتدانشجوی دکترا، گروه علوم محیطزیست، دانشکده منابع طبیعی و محیطزیست،دانشگاه آزاد اسلامی، واحد علوم و تحقیقات، تهران، ایرانامیر حسام حسنیاستاد، گروه مهندسی محیطزیست، دانشکده منابع طبیعی و محیطزیست، دانشگاه آزاد اسلامی، واحد علوم و تحقیقات، تهران، ایران0000-0003-2569-5446همایون احمد پناهیاستاد، گروه شیمی، دانشکده علوم پایه، دانشگاه آزاد اسلامی، واحد تهران مرکزی، تهران، ایرانالهام منیریدانشیار، گروه شیمی و مهندسی شیمی، دانشکده علوم پایه، دانشگاه آزاد اسلامی، واحد ورامین-پیشوا، ورامین، ایرانمسعود منوریدانشیار، گروه علوم محیطزیست، دانشکده منابع طبیعی و محیطزیست،دانشگاه آزاد اسلامی، واحد علوم و تحقیقات، تهران، ایرانJournal Article20191024The entry of herbicides into drinking water supply sources can have devastating effects on human health and the environment. Therefore, removal of them from the aquatic environment is essential, in order to preserve the environment. Therefore, this study was conducted with the aim to investigate the isotherm absorption of graphene oxide modified by organic dendrimers to remove Butachlor toxin from the aquatic environment. In the present study, operating magnetic graphene oxide was produced by absorption of covalent bonds and used as adsorbent. Synthetic adsorbent properties were analyzed by FTIR, XRD, SEM, TEM, TGA, VSM and EDS. Also, the effects of pH parameters, contact time, contaminant concentration, adsorbent amount, temperature and reusability on adsorption absorption capacity were investigated and optimal conditions were determined. The absorption results were described by Langmuir, Freundlich, Temkin and kinetic adsorption models by first-order and quasi-second-order models and thermodynamic equations. The results indicated that functionalized graphene oxide effectively absorbs Butachlor and absorption percentage is significantly affected by the examined parameters. By increasing the time to 45 minutes, increasing the pH to 5, increasing the amount of adsorbent to 3 g/L and the concentration of Butachlor toxin to 10 mg/L and increasing the temperature to 25 ⁰C, the rate of absorption of Butachlor toxin has increased to 95.4%. Toxin absorption increased from 37 to 50 ⁰C, and after ten re-uses of the adsorbent, the absorption rate decreased by only 6.5%. Under optimal conditions, the adsorbent was able to remove 86.3% of Butachlor toxin in the real sample with a standard deviation of 6.06%. The Langmuir isotherm described the absorption process well (R<sup>2</sup> = 0.99). Synthesized nano-adsorbent is an efficient, powerful and heat-sensitive adsorbent for removing Butachlor from the aquatic environment.<strong>ورود علفکشها به منابع تأمین آب شرب میتواند اثرات مخربی بر سلامت انسان و محیطزیست داشته باشد. بنابراین برای حفظ محیطزیست حذف آنها از محیط آبی امری ضروری است. بنابراین این پژوهش با هدف بررسی ایزوترم جذب گرافن اکساید اصلاح شده توسط دندریمرهای آلی برای حذف سم بوتاکلر از محیط آبی انجام شد. در این پژوهش گرافن اکساید مغناطیسی عاملدار شده به روش جذب پیوندهای کووالانسی تولید و بهعنوان جاذب استفاده شد. مشخصات جاذب سنتز شده توسط FTIR، XRD، SEM و TEM آنالیز شد. همچنین تأثیر پارامترهای pH، زمان تماس، غلظت آلاینده، مقدار جاذب، دما و قابلیت استفاده مجدد بر ظرفیت جذب جاذب بررسی شد و شرایط بهینه تعیین شد. یافتههای جذب بهوسیله مدلهای ایزوترم لانگمیر و فروندلیچ شرح داده شدند. نتایج نشان داد که گرافن اکساید مغناطیسی عاملدار شده بهطور مؤثر سم بوتاکلر را جذب میکند و درصد جذب بهطور قابلتوجهی تحت تأثیر پارامترهای بررسی شده است. با افزایش زمان تا 45 دقیقه، افزایش pH تا مقدار5، افزایش مقدار جاذب تا 3 گرم بر لیتر و غلظت سم بوتاکلر تا 10 میلیگرم در لیتر و افزایش دما تا 25 درجه سلسیوس، مقدار جذب سم بوتاکلر تا 4/95 درصد افزایش یافته است. واجذب سم از دمای 37 تا 50 درجه سلسیوس افزایش یافته است و بعد از 10 بار استفاده مجدد از جاذب، مقدار جذب تنها 5/6 درصد کاهش یافت. جاذب در شرایط بهینه قادر به حذف 3/86 درصد از سم بوتاکلر در نمونه واقعی با انحراف استاندارد 06/6 درصد شد. ایزوترم لانگمیر فرایند جذب را بهخوبی توصیف کرد (99/0=<sup>2</sup>R). نانوجاذب سنتز شده، یک جاذب کارآمد و توانمند و حساس به گرما برای حذف سم بوتاکلر از محیط آبی است.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321An Intelligent Hybrid Model for Determining Public-Private Partnership in Iranian Water and Wastewater Industry Based on Collective Tree Algorithmsمدل ترکیبی هوشمند تعیین روش مشارکت عمومی- خصوصی صنعت آب و فاضلاب ایران بر مبنای الگوریتمهای جمعی درختی699012801110.22093/wwj.2020.211331.2970FAملیحه اسکندریدکترای مدیریت فناوری اطلاعات، گروه مدیریت صنعتی، دانشکده مدیریت و حسابداری، دانشگاه علامه طباطبائی، تهران، ایرانمحمدتقی تقویفرددانشیار، گروه مدیریت صنعتی، دانشکده مدیریت و حسابداری، دانشگاه علامه طباطبائی، تهران، ایرانایمان رئیسی وانانیاستادیار، گروه مدیریت صنعتی، دانشکده مدیریت و حسابداری، دانشگاه علامه طباطبائی، تهران، ایرانسید سروش قاضی نوریاستادیار، گروه مدیریت صنعتی، دانشکده مدیریت و حسابداری، دانشگاه علامه طباطبائی، تهران، ایرانJournal Article20191224One of the pillars of any country’s development is access to safe water and sanitation, so it is important to execute water and wastewater projects in the shortest possible time. In this regard, considering the emergence of various methods of partnership, choosing the right approach has become one of the most important issues in this industry. Therefore, a proper investment method in this field has always been the concern of decision makers. Using the database of partnership projects and data mining algorithms in the water and wastewater sector, we have designed a model to predict a proper way for public-private partnership projects. In this research, CRISP data mining method was applied to the data from 176 projects. After understanding and identifying the data, they were cleaned by deleting outliers and noisy data, and missing values were replaced. Then, the process of data classification was performed using decision tree and machine learning algorithms, and necessary analysis was performed. Also, the indicators of PPP were extracted and prioritized. K-fold cross validation method is used for validation and dividing the data. Based on the modeling and considering the data preparations and data mining methods, the stacking method is suitable for predicting and determining the type of public-private partnership contract in the implementation of each project of water and wastewater industry, which has an accuracy of 86.27%. In the pre-processing section, the combined COF method for deleting outliers and entropy factors for feature selection was used. Using the model, the success rate of each project can be predicted and an appropriate PPP contractual template for any water and wastewater project can be proposed. In addition, by entering the information of each new project, the impact of the improvement of each indicator can be easily examined.<strong>دسترسی به آب سالم و دفع بهداشتی فاضلاب از ارکان توسعه هر کشور بوده و ضروری است که این طرحها در کوتاهترین زمان ممکن تکمیل شود. از سوی دیگر با توجه به ظهور انواع روشهای مشارکت عمومی- خصوصی، انتخاب روش مناسب مشارکت، یکی از مسائل مهم بخش آب و فاضلاب بوده و این صنعت همواره نیازمند مدلی برای تصمیمگیری در خصوص نحوه و روش سرمایهگذاری در منطقه و یا طرح خاص بوده است. با توجه به وجود پایگاه داده از اطلاعات پروژههای مشارکتی در بخش آب و فاضلاب، میتوان با استفاده از دادههای بهدست آمده و الگوریتمهای کشف الگو و تصمیمگیری دادهکاوی، مدل سرمایهگذاری و روش مناسب اجرای پروژه را تعیین کرد. در این پژوهش با بهرهگیری از دادههای ۱۷۶ پروژه مشارکتی بخش آب و فاضلاب و استفاده از روش اجرای پروژههای دادهکاوی یعنی فرایند کریسپ، مدل مشارکت عمومی- خصوصی صنعت آب و فاضلاب استخراج شد. پس از تشریح و درک داده، مراحل پاکسازی و حذف دادههای پرت اجرا شده است. در مرحله دستهبندی، با تکنیکهای درختی و یادگیری ماشین، طبقهبندی موفقیت و شکست پروژهها و تحلیلهای لازم انجام و شاخصهای مشارکت عمومی- خصوصی بهترتیب اولویت استخراج شد. بهمنظور اعتبارسنجی و تقسیم دادهها، از روش اعتبارسنجی ضربدری استفاده شد. بر مبنای مدلسازی انجام شده و با در نظر گرفتن انواع روشهای پیشپردازش و دادهکاوی، روش استکینگ با دقت 27/86 درصد، بهعنوان روش مناسب پیشبینی و تعیین نوع قرارداد مشارکت عمومی- خصوصی در اجرای هر پروژه بخش آب و فاضلاب معرفی شد. در بخش پیشپردازش نیز روش ترکیبی Connectivity-based Outlier Factor برای حذف داده پرت و شاخص آنتروپی برای انتخاب ویژگی استفاده شد. با توجه به مدل پیشنهادی، علاوه بر معرفی قالب قراردادی مشارکتی مناسب برای اجرای هر گروه از پروژههای بخش آب و فاضلاب و معرفی قالب قراردادی مناسب در هر استان، میتوان میزان موفقیت هر طرح را در هر یک از قالبهای قراردادی پیشبینی و تأثیر بهبود هر یک از شاخصها را در افزایش موفقیت پروژه بررسی کرد.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Uncertainty and Sensitivity Analysis of Solute Contaminant Transport Simulation in Groundwater (Case Study: Qazvin Plain)تحلیل عدمقطعیت و حساسیت مدل انتقال آلاینده محلول در آبهای زیرزمینی (مطالعه موردی: دشت قزوین)9110512800710.22093/wwj.2020.229174.3016FAناهید سادات جعفریدانش آموخته کارشناسی ارشد، گروه مهندسی آب و سازههای هیدرولیکی، دانشکده مهندسی عمران، آب
و محیطزیست، دانشگاه شهید بهشتی، تهران، ایرانسعید علیمحمدیدانشیار، گروه مهندسی منابع آب، دانشکده مهندسی عمران، آب و محیطزیست، دانشگاه شهید بهشتی، تهران، ایرانJournal Article20200502Groundwater contaminant transport modeling is a useful tool for identifying how pollutants fate and transport in porous aquifer environments. These models include several parameters, which are often estimated based on personal judgment or in the best case, based on limited field measurements. Therefore, the input data of simulation models are not accurate and contain several errors. The purpose of this study is parameter uncertainty and sensitivity analysis in the groundwater solute contaminants transport modeling using probability theory. First, governing equations for groundwater flow and solute contaminant transport have been presented. Then, using MOFLOW for modeling groundwater flow and MT3DMS for modeling solute contaminant transport in a hypothetical problem and using effective parameters in a case study (Qazvin plain), uncertainty analysis through the Monte Carlo method was done. To illustrate the uncertainty analysis, the Complementary Cumulative Distribution Functions (CCDF) of Chloride and Nitrate graphs have been computed. Then using random samples, generated in uncertainty analysis step, local and global sensitivity analysis of solute transport model parameters have been determined. Result: Using maximum concentration of solute contaminant as a model output, the results of the local sensitivity analysis show that the most sensitive parameters are hydraulic conductivity (K), decay rate constant (λ), porosity (θ), distribution coefficient (K<sub>d</sub>), and dispersivity (D) respectively. While using time to maximum concentration as output variable, leads to the following order of sensitivity: K, K<sub>d</sub>, θ, D, and λ. On the other hand, the global sensitivity analysis using maximum concentration shows that the order of sensitivity is: K, λ, θ, D, and K<sub>d</sub>, and using time to maximum concentration it is: K, K<sub>d</sub>, D, λ, and θ respectively. According to the CCDF of Chloride, concentrations of 5%, 50% and 95% equal 205.5, 196 and 185.4 mg/L respectively. Also, according to the CCDF of Nitrate the concentrations of 5%, 50%, and 95% equal 56, 54.125 and 51.5 mg/L respectively. All five parameters are sensitivite in solute transport modeling. The local and global sensitivity analysis show more or less the same results. In general, the sensitivity ranking of parameters is K, λ, Kd, θ, and D.<strong>مدلسازی کیفی آبهای زیرزمینی ابزاری مفید برای شناسایی چگونگی انتقال آلایندهها در محیط متخلخل آبخوان است. این مدلها شامل پارامترهای متعددی هستند که اغلب بر اساس پژوهشهای قبلی یا قضاوت کارشناسی برآورد میشوند یا در بهترین شرایط بر اساس اندازهگیریهای محدود میدانی برآورد میشوند. در نتیجه دادههای ورودی به مدلهای شبیهسازی، دقیق نبوده و همراه با خطا هستند که این خطاها باعث به وجود آمدن عدمقطعیت در نتایج مدل شبیهسازی میشود. هدف این پژوهش تحلیل عدمقطعیت و تحلیل حساسیت پارامترهای مدل جریان و مدل انتقال آلاینده محلول در آب زیرزمینی و تعیین پارامترهای حساس بر انتقال آلاینده بود. بهاین منظور ابتدا با استفاده از مدل فرضی و تحلیل حساسیت به دو روش موضعی و جامع، پارامترهای حساس بر انتقال آلاینده تعیین شد. پارامترهای مؤثر بر حداکثر غلظت آلاینده محلول از تحلیل حساسیت موضعی بهترتیب هدایت هیدرولیکی، ضریب کاهشی، تخلخل، ضریب توزیع و ضریب پخشیدگی و پارامترهای مؤثر بر زمان رسیدن به حداکثر غلظت بهترتیب هدایت هیدرولیکی، ضریب توزیع، تخلخل، ضریب پخشیدگی و ضریب کاهشی بودند. پارامترهای مؤثر بر حداکثر غلظت آلاینده محلول با توجه به نتایج تحلیل حساسیت جامع نیز بهترتیب هدایت هیدرولیکی، ضریب کاهشی، تخلخل، ضریب پخشیدگی و ضریب توزیع و پارامترهای مؤثر بر زمان رسیدن به حداکثر غلظت بهترتیب هدایت هیدرولیکی، ضریب توزیع، ضریب پخشیدگی، ضریب کاهشی (یا نرخ زوال) و تخلخل بودند. سپس مدلسازی جریان با مدل MODFLOW و مدلسازی انتقال آلایندهها با مدل MT3DMS آب زیرزمینی منطقه بررسی شده (دشت قزوین) بر اساس اطلاعات کیفی مربوط به یونهای کلراید و نیترات انجام شد و با استفاده از پارامترهای مدل، تولید متغیرهای تصادفی به روش مونتکارلو که مناسب برای توابع پیچیده است، انجام شد. برای بیان تحلیل عدمقطعیت نمودارها تابع توزیع تجمعی مکمل CCDF غلظت کلراید و نیترات محاسبه و رسم شده است. با توجه به این نمودار تغییرات غلظت کلراید با احتمال 5 درصد برابر با 5/205 میلیگرم در لیتر، با احتمال 50 درصد برابر با 5/196 میلیگرم در لیتر، احتمال 95 درصد برابر با 4/185 میلیگرم در لیتر است. همچنین با توجه به نمودار CCDF نیترات، تغییرات غلظت نیترات با احتمال 5، 50 و 95 درصد بهترتیب برابر 56، 125/54 و 5/51 میلیگرم در لیتر حاصل شد. نتایج دو روش تحلیل حساسیت موضعی و جامع شبیه هم هستند. شایان ذکر است که این نتیجه مربوط به مدل فرضی است و ممکن است در شرایط دیگر نتایج متفاوتی حاصل شود.</strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Investigation of the Sediment Formation Factors in Drinking Water Distribution Network of the City of Sough and its Relationship to Water Propertiesبررسی عوامل تشکیل رسوب در شبکه توزیع آب شرب شهر سوق و رابطه آن با خواص آب10612412807110.22093/wwj.2020.223858.3004FAعبدالحسین صالحی سروکدانشجوی دکترا، گروه آلودگی محیطزیست، دانشگاه آزاد اسلامی واحد یزد، یزد، ایرانعلی المدرسیدانشیار، گروه سنجش از دور و GIS، دانشگاه آزاد اسلامی واحد یزد، یزد، ایرانسید ابوالقاسم میر حسینیاستادیار، گروه آلودگی محیطزیست، دانشگاه آزاد اسلامی واحد یزد، یزد، ایرانمسعود شیشه بردانشیار، گروه شیمی، دانشگاه آزاد اسلامی واحد یزد، یزد، ایرانعلی اکبر جمالیدانشیار، گروه سنجش از دور- GIS و منابع طبیعی، دانشگاه آزاد اسلامی واحد میبد، میبد، ایرانعبدالحسین کنگازیاناستادیار، گروه زمینشناسی، دانشکده مهندسی، دانشگاه آزاد اسلامی واحد اصفهان (خوراسگان)، اصفهان، ایرانJournal Article20200318Given the increasing consumption of potable water in the world, efforts to adopt new solutions for the obtainment of the right amount of desirable water is essential. One of the chief issues facing the majority of industries including water industry is corrosion and sedimentation. The present study was conducted to address the corrosion and sedimentation of drinking water supply and distribution reservoirs in the city of Sough, Kohgiloye-Boyer-Ahmad province. Through descriptive analysis, the Langelier, Raisner, Pokorius, and aggressive indices to determine the corrosion and sedimentation potential of the water supply network were used. This study was aimed measure chemical and physicochemical information of 84 water samples from wells, water reservoirs and allocated water supply network of the area. The samples were collected and analyzed from 2007 to 2016 by the provincial Water and Wastewater Company. The results indicated that the mean indices were -0.589±0.63 (low to moderate corrosion), 8.470±0.797, (low to moderate corrosion), 7.472±0.228 (low to moderate corrosion), respectively and 12.015±0.227 (mild aggressive or very corrosive) respectively. The water supply sources under investigation had low to moderate corrosion and little tendency to develop eggshell sedimentation. The water supply sources of the study area had low to moderate corrosion and had a slight tendency for eggshell sedimentation. Drinking water allocated to Sough water supply network in the direction of joint drinking water transmission of Dehdasht and Sough within 17 km of joint water supply from Sepah Tapeh reservoir (Dehdasht and Sough joint) is separated and directed, within 15 km by the transfer line and pump station, to Sough city. The average values of corrosion and sedimentation indices of the city of Sough water supply and distribution network (Lanzeley, Reisner, Pokoris and aggressive) were 0.63, 6.8, 7.28 and 12.8, respectively which indicate tendency toward sedimentation, relative tendency toward CaCO<sub>3</sub>, and non-aggressiveness. Despite the fact that the average pH of the joint water resources of both cities was 7.78. In summer, the water pH of Sough allocated water network increased to 8.5. Values and mean values of corrosion and sedimentation indices of Sough water supply network during hot seasons of the year show that the water of this network tends to precipitate. The findings also suggest that the average water temperature of the allocated water supply network in these 15 kilometers of transition which includes the transmission line and surfaced metal reservoirs had an increase in temperature around 10 °C. This temperature rise was due to the environment temperature (above 48 °C), the hot water in metal reservoirs and the surfaced steel transmission line in water supply network components. This physical change of water temperature is the main factor behind sedimentation.<strong><strong>با توجه به افزایش مصرف آب شرب در جهان، تلاش برای بهکارگیری راهکارهای جدید برای دست یافتن به مقدار مناسب آب با کیفیت مطلوب لازم است. یکی از مسائل عمدهای که اکثر صنایع از جمله صنعت آب با آن مواجهاند، خورندگی و رسوبگذاری است. این پژوهش بهمنظور بررسی عوامل رسوبگذاری و خورندگی منابع تأمین و توزیع آب شرب شهر سوق در استان کهگیلویه و بویراحمد انجام شد. در این پژوهش با استفاده از شاخصهای لانژلیه، رایزنر، پوکوریوس و تهاجمی بهصورت مطالعه توصیفی بهمنظور تعیین پتانسیل خوردگی و رسوبگذاری آب شبکه آبرسانی، اطلاعات شیمیایی و فیزیکوشیمیایی 84 نمونه آب مربوط به چاههای تغذیه، مخازن آب و شبکه آبرسانی اختصاصی این منطقه استفاده شدند. نمونهها بین سالهای 1386 تا 1395 توسط شرکت آب و فاضلاب شهری استان جمعآوری و آنالیز شدند. با توجه به این اطلاعات، اندیسهای لانژلیه، رایزنر، پوکوریوس و تهاجمی برای این نمونهها محاسبه شد و یافتههای بهدست آمده از بهکارگیری شاخصهای فوق نشان داد که متوسط شاخصها بهترتیب 63/0±598/0 خوردگی کم تا متوسط، 797/0± 470/8 خوردگی کم تا متوسط، 286/0±472/7 خوردگی کم تا متوسط و 227/0± 015/12 تهاجمی ملایم یا خوردگی خیلی کم بود. منابع تأمین آب منطقه بررسی شده دارای خوردگیکم تا متوسط بودند و اندکی تمایل به ایجاد رسوب پوسته تخممرغی داشتند. آب شرب شهر سوق در مسیر انتقال آب شرب مشترک شهر دهدشت و سوق در فاصله 17 کیلومتری از محل منابع تأمین آب مشترک (چاها) از مخزن ذخیره تپه سپاه (مشترک شهر دهدشت و سوق) مجزا شده و به فاصله 15 کیلومتر توسط خط انتقال و ایستگاه پمپاژ آب بهسمت شهر سوق هدایت میشود. میانگین مقدار شاخصهای خورندگی و رسوبگذاری شبکه اختصاصی تأمین و توزیع آب شهر سوق (لانزلیه، رایزنر، پوکوریس وتهاجمی) بهترتیب 63/.، 8/6، 28/7 و 8/12 بهدست آمد که تمایل به رسوب، بهطور متوسط تمایل به تهنشست CaCO<sub>3</sub>، غیرتهاجمی است. علیرغم این واقعیت که pH متوسط منابع تأمین آب مشترک هر دو شهر 78/7 بود. در فصل تابستان pH آب شبکه اختصاصی شهر سوق به 5/8 افزایش یافت. مقدار و میانگین مقدار شاخصهای خورندگی و رسوبگذاری شبکه اختصاصی آبرسانی شهر سوق در فصل گرم سال نشان میدهد که آب این شبکه تمایل به رسوب دارد. بر اساس یافتههای این بررسی میانگین دمای آب شبکه آبرسانی اختصاصی در این 15 کیلومتر انتقالی که شامل خط انتقال و مخازن ذخیره فلزی روکار هستند، حدود10 درجه سلسیوس افزایش دما داشته است. این افزایش دما ناشی از دمای محیط بیش از 48 درجه سلسیوس و گرم شدن آب در مخازن ذخیره فلزی و خط انتقال فولادی روکار در اجزای شبکه آبرسانی آب اختصاصی شهر سوق هستند که این تغییر فیزیکی آب یا دما عامل اصلی تشکیل رسوب است.</strong></strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Determining the Contamination Source in Water Distribution Networks Using Genetic Algorithmتعیین مشخصات منبع آلودگی در شبکههای توزیع آب با استفاده از الگوریتم ژنتیک12513512807010.22093/wwj.2020.206667.2942FAسجاد خلیلیدانشآموخته کارشناسی ارشد مهندسی عمران- آب، دانشکده مهندسی عمران،
پردیس دانشکدههای فنی، دانشگاه تهران، تهران، ایرانمسعود تابشاستاد، دانشکده مهندسی عمران، پردیس دانشکدههای فنی، دانشگاه تهران، تهران، ایران0000-0002-8982-8941الهام قائمیدانشجوی دکترای، مهندسی عمران محیطزیست، دانشکده مهندسی عمران،
پردیس دانشکدههای فنی، دانشگاه تهران، تهران، ایرانJournal Article20191026Contamination of drinking water is known as a major threat of water security around the world. As contamination enters a water distribution network, it spreads rapidly into the network and poses health and safety risks to the community. Using a set of sensors to report the concentration of chlorine or any other chemical, useful observations can be made to detect, identify and manage pollution. Based on these observations, location, concentration and start time of contamination can be determined and decision makers can be informed. In this paper, a simulation-optimization approach is used to solve the problem of contamination source characterization in which the EPANET software is used as a simulator and the Genetic Algorithm is used as an optimizer. The model developed in this paper is implemented on EPANET example 3. Modeling of water distribution networks uses information as input data which can cause error in model simulation. Pipe roughness and chlorine deterioration rate are among these inputs. The model has been implemented to find the location, start time and concentration of inlet pollution and the effect of pipe roughness and chlorine deterioration rate on the model responses have been investigated. The pollution entry scenario is applied to the network and the model presented is accurate in finding the location and time of the contamination. As the variables increase, the model accurately estimates the location and time of entry of the contamination but does not have complete accuracy in estimating the concentration of contamination, which is calculated with standard deviation of σ = 4.8% -8.1%.<strong>آلوده شدن آب آشامیدنی بهعنوان یک تهدید برای امنیت آب در سراسر جهان شناخته میشود. در شبکههای توزیع آب، آلودگی پس از ورود به شبکه بهسرعت گسترش یافته و خطرات بهداشتی و جانی برای جامعه ایجاد میکند. با استفاده از مجموعهای از حسگرها که غلظت کلر یا هر ماده شیمیایی دیگر را گزارش دهند، میتوان مشاهدات مفیدی برای تشخیص، شناسایی و مدیریت آلودگی ارائه داد. از جمله بر اساس این مشاهدات می</strong><strong></strong><strong>توان محل، زمان و غلظت آلودگی ورودی به شبکه را تعیین و به تصمیمگیرندگان اعلام کرد. در این پژوهش برای حل مسئله تعیین مشخصات منبع آلودگی، از یک رویکرد شبیهسازی-بهینهسازی استفاده میشود که در آن نرمافزار شبیهسازی شبکههای آب تحت فشار </strong><strong>EPANET</strong><strong> بهعنوان شبیهساز و الگوریتم ژنتیک بهعنوان بهینهساز بهکار رفته است. مدل توسعهیافته در این پژوهش، بر روی </strong><strong>EPANET Example 3</strong><strong> اجرا شد. در مدلسازی شبکههای توزیع آب از اطلاعاتی بهعنوان دادههای ورودی استفاده شد که میتوانند سبب بروز خطا در شبیهسازی مدل شوند. زبری لولهها و نرخ زوال کلر ازجمله این ورودیها هستند. مدل برای پیدا کردن مکان، زمان و غلظت آلودگی ورودی اجرا شده و تأثیر زبری لولهها و نرخ زوال کلر بر جوابهای مدل بررسی شده است. سناریوی ورود آلودگی بر روی شبکه اعمال شده و مدل ارائه شده در پیدا کردن مکان و زمان آلودگی کاملاً دقیق است. با افزایش متغیرها، مدل مکان و زمان ورود آلودگی را بهدرستی ارزیابی کرده، اما در ارزیابی غلظت آلودگی دقت کامل را ندارد و غلظت آلودگی با انحراف از معیار 1/8%-8/4%=</strong><strong>σ</strong><strong> محاسبه میشود.</strong>
<strong> </strong>مهندسین مشاور طرح و تحقیقات آب و فاضلاب اصفهانمجله آب و فاضلاب1024-593632120210321Removal of Arsenic from Aqueous Solution Using Single-Walled Carbon Nanotubes Modified with Poly Allylamine Hydrochlorideحذف آرسنیک از محلول آبی با استفاده از نانولولههای کربنی تک دیواره اصلاح شده با پلی آلیلآمین هیدروکلرید13614612806910.22093/wwj.2020.232654.3025FAمرتضی کاظمآبادیدانشجوی کارشناسی ارشد، دانشکده
محیطزیست، واحد علوم وتحقیقات، دانشگاه آزاد اسلامی، تهران، ایرانمهساسادات میرعلینقیاستادیار، گروه شیمی، دانشکده علوم پایه، واحد ورامین- پیشوا، دانشگاه آزاد اسلامی، ورامین، ایرانهمایون احمدپناهیاستاد، گروه شیمی، دانشکده علوم پایه، دانشگاه آزاد اسلامی، واحد تهران- مرکز، تهران، ایرانرضا حاجیسیدمحمدشیرازیاستادیار، گروه منابع آب، دانشکده محیطزیست، دانشگاه آزاد اسلامی، واحد علوم و تحقیقات، تهران، ایرانJournal Article20200524Arsenic in water is one of the highly toxic elements which has harmful influences on the human health and ecosystems. To address this problem, single-walled carbon nanotubes modified with poly (allylamine hydrochloride) (PAH/Ox-SWCNT) composite were synthesized and applied as an adsorbent for arsenic removal from aqueous solution in this study. The properties of PAH/Ox-SWCNT nanocomposite were characterized using scanning electron microscopy, Thermogravimetric, Fourier-transform infrared spectroscopy, and X-ray powder diffraction analysis. Batch experiments were executed to determine the ability of PAH/Ox-SWCNT to adsorb As from solution under various operational conditions. The experimental data were fitted by pseudo-first-order kinetic and pseudo-second-order kinetic models by nonlinear regression analysis using Mathematica software. Langmuir and Freundlich models were employed to describe the adsorption equilibrium isotherms. The removal percentage of As increased with initial solution pH from 3 to 7 while it decreased with the initial concentration of As. Moreover, the enhancement of contact time caused better adsorption efficiencies. The percentage removal of As using 10 mg of synthesized nanocomposite was more than 90% at pH=7 and contact time of 30 min. The adsorption experimental data had better agreement with pseudo-second-order kinetic and the Freundlich isotherm models. The maximum adsorption capacity of PAH/Ox-SWCNT was 275.07 mg/g at 298 K. The As removal percentage after eight adsorption-desorption cycles was higher than 65%. All results implied that the synthesized PAH/Ox-SWCNT could potentially be a promising adsorbent in arsenic water remediation.<strong>آرسنیک موجود در آب یکی از عناصر بسیار سمّی است که اثرات زیانباری بر سلامت انسان و اکوسیستم میگذارد. برای رفع این مشکل، در این پژوهش کامپوزیت نانولولههای کربنی تک دیواره اصلاح شده با پلی آلیلآمین هیدروکلرید </strong><strong>(</strong><strong>PAH/Ox-SWCNT)</strong><strong> سنتز شد و بهعنوان جاذب برای حذف آرسنیک از محلول آبی بهکار رفت. ویژگیهای نانوکامپوزیت با آنالیزهای میکروسکوپ الکترونی روبشی، آنالیز گرویمتری، طیفبینی تبدیل فوریه مادون قرمز و الگوی پراش پرتو </strong><strong>x</strong><strong> شناسایی شد. آزمایشهای جذب سطحی برای تعیین کارایی </strong><strong>PAH/Ox-SWCNT</strong><strong> در جذب سطحی آرسنیک از محلول در شرایط عملیاتی مختلف انجام شد. دادههای تجربی با مدلهای سینتیکی شبهمرتبه اول و دوم به روش رگرسیون غیرخطی با استفاده از نرمافزار </strong><strong>Mathematica</strong><strong> برازش شد. مدلهای لانگمیر و فروندلیچ برای توصیف همدماهای تعادلی جذب بهکار برده شدند. درصد حذف </strong><strong>As</strong><strong> با افزایش </strong><strong>pH</strong><strong> اولیه محلول از 2 تا 7 افزایش یافت، در صورتی که با افزایش غلظت اولیه </strong><strong>As</strong><strong> کاهش پیدا کرد. بهعلاوه، افزایش زمان تماس موجب بازده بیشتر جذب سطحی شد. درصد حذف </strong><strong>As</strong><strong> با استفاده از 10 میلیگرم از نانوکامپوزیت سنتزی، در </strong><strong>pH</strong><strong> برابر 7 و زمان تماس 30 دقیقه بیش از 90 درصد بود. حداکثر ظرفیت جذب سطحی در دمای298 درجه سلسیوس، 07/275 میلیگرم بر گرم بهدست آمد. فرایند جذب از مدل سینتیکی شبهمرتبه دوم و مدل همدمای فروندلیچ پیروی کرد. همچنین، درصد حذف </strong><strong>As</strong><strong> پس از هشت چرخه جذب-واجذب بیش از 65 درصد بود. نتایج نشان داد که </strong><strong>PAH/Ox-SWCNT</strong><strong> سنتزی احتمالاً میتواند جاذب نویدبخشی برای پاکسازی آب آلوده به آرسنیک باشد.</strong>