text
article
2017
per
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
https://www.wwjournal.ir/article_34111_89e3e2e1d320156e129bd194d20277fb.pdf
.
text
article
2017
per
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
https://www.wwjournal.ir/article_34112_0878c451af5a80b5b3b04fe7955216de.pdf
A Novel Algorithm (G-JPSO) and Its Development for the Optimal Control of Pumps in Water Distribution Networks
Rasoul
Rajabpour
PhD Student, Department of Civil Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
author
Nasser
Taleb Beidokhti
Prof. of Civil and Environmental Engineering, University of Shiraz, Shiraz
author
Gholamreza
Rakhshanderoo
Prof. of Civil and Environmental Engineering, University of Shiraz, Shiraz
author
text
article
2017
per
Recent decades have witnessed growing applications of metaheuristic techniques as efficient tools for solving complex engineering problems. One such method is the JPSO algorithm. In this study, innovative modifications were made in the nature of the jump algorithm JPSO to make it capable of coping with graph-based solutions, which led to the development of a new algorithm called ‘G-JPSO’. The new algorithm was then used to solve the Fletcher-Powell optimal control problem and its application to optimal control of pumps in water distribution networks was evaluated. Optimal control of pumps consists in an optimum operation timetable (on and off) for each of the pumps at the desired time interval. Maximum number of on and off positions for each pump was introduced into the objective function as a constraint such that not only would power consumption at each node be reduced but such problem requirements as the minimum pressure required at each node and minimum/maximum storage tank heights would be met. To determine the optimal operation of pumps, a model-based optimization-simulation algorithm was developed based on G-JPSO and JPSO algorithms. The model proposed by van Zyl was used to determine the optimal operation of the distribution network. Finally, the results obtained from the proposed algorithm were compared with those obtained from ant colony, genetic, and JPSO algorithms to show the robustness of the proposed algorithm in finding near-optimum solutions at reasonable computation costs.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
3
14
https://www.wwjournal.ir/article_15510_82950a0b7f9fb31d114411b0cb605c33.pdf
3D Numerical Investigation of the Flow Pattern in Settling Basins by SSIIM2 Software
Edris
Merufinia
PhD Student, Young Researchers and Elite Club, Mahabad Branch, Islamic Azad University, Mahabad, Iran
author
Adel
Asnaashari
PhD, Young Researchers and Elite Club, Mahabad Branch, Islamic Azad University, Mahabad, Iran
author
Yousef
Hassanzadeh
Prof., Faculty of Civil Engineering, University of Tabriz, Tabriz, Iran
author
Saeid
Khoshtinat
PhD Student, Islamic Azad University, Roodehen Branch, Member of Young Research Club, Roudehen, Iran
author
Hassan
Ahmadi
Assist. Prof., Islamic Azad University, Roodehen Branch, Member of Young Research Club, Roudehen, Iran
author
text
article
2017
per
Settling basins are considered as a major and important component in conventional water treatment processes. The high cost of constructing these basins accounts for approximately 30% of the total capital investment of water treatment plants. Hence, it is essential to model and optimize their performance beforehand. In settling and sedimentation basins, different areas of flow including secondary and rotational flows occur due to the velocity gradient. Such phenomena cause short paths, increase flow stationary and dead zones, and change the mixing rates of the flow, which collectively prevent laminar conditions to be created for the sedimentation process, and thereby reduce process efficiency. The remedy is to reduce as far as possible the dead zones in the flow. The first step to optimize a settling basin is to calculate accurately the velocity field and the volume of rotation zones. The present study presents the numerical simulation of a flow in a rectangular basin. Continuity and Navier-Stokes equations are solved using finite volume method. A 3D flow simulation is performed using the standard k-ε turbulence model for settling basins with and without baffles. Finally, the numerical results obtained are compared with experimental results reported elsewhere.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
15
23
https://www.wwjournal.ir/article_15675_002b735445af92e6812b743a7639822e.pdf
Sulfate Adsorption on Iron Nanocomposites on Graphene Oxide and Activated Carbon Beds
Rezvan
Birooni
MSc in Chemical Engineering, Faculty of Chemical Engineering, Islamic Azad University, Mahsharh Branch, Mahshahr, Iran
author
Masoumeh
Mirzaei
Ass. Prof. of Chemical Engineering, Faculty of Chemical Engineering, Islamic Azad University, Mahsharh Branch, Mahshahr, Iran
author
text
article
2017
per
This study is an experimental investigation of sulfate removal efficiency using iron nanocomposites on graphene oxide and activated carbon beds. The graphene oxide used was synthesized according to the Hummer method during which process graphene oxide and activated carbon were added. The effects of various parameters including adsorbent content, pH, and contact time on adsorption were investigated. Furthermore, the data were subjected to kinetic studies. Results revealed that the highest absorption rates of 84% and 62% were achieved for iron on the graphene oxide and activated carbon beds, respectively, when 0.06 g of the adsorbent was used at pH =11 over a contact time of 9 hours. It was also found that the kinetic pseudo-second-order model best fit the data. Finally, the results indicated that the two environmentally-friendly adsorbents have a good potential for removing sulfate from aqueous solutions.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
24
32
https://www.wwjournal.ir/article_15524_9fa46a098dfcab59f6b0838cca754455.pdf
Adsorption of Malachite Green Dye Using Modified γ-Alumina
Roghaye
Zarrinkamar
MSc Student of Applied Chemistry, Ahar Branch, Islamic Azad University, Ahar, Iran
author
Parvin
Gharbani
Assist. Prof. of Applied Chemistry, Ahar Branch, Islamic Azad University, Ahar, Iran
author
text
article
2017
per
Modified γ-Alumina was used for the adsorption of the cationic dye malachite green (MG) from aqueous solutions. The properties of the modified particles were initially determined by FT-IR, XRD, SEM, and EDAX. The effects of such parameters as initial dye concentration, contact time, initial pH, adsorbent dose, and temperature on dye removal were investigated and the pHzpc of the adsorbent was determined. Results showed that equilibrium was achieved in 60 min and MG removal increased with increasing adsorbent dosage and pH. The experimental results indicated that 0.1g of modified γ-Alumina was capable of removing 91.61% of the MG dye from an initial concentration of 50 mg L-1 at pH=10. Results of isotherm and kinetic studies revealed that adsorption of Malachite Green dye onto modified γ-Alumina best fitted the Temkin isotherm and pseudo-second-order kinetic models.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
33
41
https://www.wwjournal.ir/article_16226_f9941de396ea385f92fd284692eaf91c.pdf
Cyanide Removal Efficiency of Photocatalytic Nanoparticles Stabilized on Glass Microbeads Under Sun Irradiation
Neda
Masoudipour
Former Graduate Student of Environmental Health Engineering, Faculty of Public Health, Shahrekord University of Medical Sciences, Shahrekord
author
Mehraban
Sadeghi
Assoc. Prof., Department of Environmental Health Engineering, Faculty of Public Health, Shahrekord University of Medical Sciences, Shahrekord
author
Mohsen
Behpour
Prof., Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran
author
Fazel
Mohammadi-Moghadam
Ass. Prof., Department of Environmental Health Engineering, Faculty of Public Health, Shahrekord University of Medical Sciences, Shahrekord, Iran
author
Morteza
Sedehi
Ass. Prof. of Biostatistics, Faculty of Public Health, Shahrekord University of Medical Sciences, Shahrekord, Iran
author
text
article
2017
per
This paper investigates cyanide photodestruction (at pH 9) using the S, N-TiO2 photocatalyst synthesized by the sol-gel method and stabilized on glass microbeads. The main raw materials were thiourea, as a source of N and S, and tetra butyl ortho titanate. The effects of S and N doses, visible light (a 400W light), sunlight, irradiation time, and different initial cyanide concentrations (50, 100, 200, and 300 ppm) were studied on cyanide photodestruction. Cyanide concentration was measured by the titration method and the photocatalyst film was characterized by X-ray diffraction (XRD), UV-Vis diffuse reflection spectroscopy (DRS), Scanning Electron Microscopy (SEM), and Energy dispersive X-ray (EDX) analysis. XRD patterns and SEM images were used to determine the nanoparticle size of the photocatalyst on glass microbeads. EDX and DRS analyses confirmed the presence of S and N as well as the activity of the photocatalyst in the visible region, respectively. The S, N-TiO2 film with 0.25 g Thiuourea proved to be the best cyanide photodestruction agent in the visible light. Based on the results obtained, S, N-TiO2/ glass microbead was capable of destroying cyanide (50 ppm) by up to 94% in the visible light and by approximately 100% in the sunlight. The results also indicated that S, N-Tio2/scoria stone was capable of destroying cyanide by 85% in the visible light and by 94% in the sunlight within 4 h. The reaction kinetic for all cyanide concentrations and two photocatalyst substrates were described by a first order equation. Finally, it was concluded that the S, N-TiO2 stabilized on glass microbeads could be effectively used as a new method for treating wastewater containing free cyanide under the sunlight.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
42
49
https://www.wwjournal.ir/article_15556_f4826e8b7ebb64d7bf08d00833f11d3a.pdf
SBAR Capability for Methyl Tertiary Butyl Ether Removal: Characterization of the Bio-granules
Bita
Ayati
Assoc. Prof. of Environmenal Engineering, Faculty of Civil and Environmental Engineering, Tarbiat Modares University, Tehran, Iran
author
Mina
Rezaei
MSc Student of Civil and Environmental Engineering, Faculty of Civil and Environmental Engineering, Tarbiat Modares University, Tehran, Iran
author
text
article
2017
per
The growing use of MTBE as a substitute for Tetraethyl lead and its adverse impacts on the environment warrant its removal from wastewater. Given the low efficiencty and the high cost associated with the chemical and physical processess commonly used for the removal of MTBE, which also release hazardous by-products into the environment, biological techniques have been explored as the more appropriate methods for its removal. This research seeks to investigate the feasibility of the SBAR system and aerobic biogranules for MTBE removal. For this purpose, a synthetic wastewater containing the materials needed for the microorganisms was used for the experiments and the pH level and DO were set to 7‒8 and 2‒5 mg/L, respectively. TEM was employed to characterize the granules. Results showed that over 90% of the initial COD (500 mg/L) was removed after 4h, which was attributed to the air stripping (28%) and sorption (1.5%) mechanisms. The resulting granules were brown in color, 2‒6 mm in size with a mean fall speed and a density equal to 0.65 cm/s and 0.055 g/ml, respectively. The superiority of the resulting granules to the flocs led to improved sedimentation in the reactor. Finally, TEM investigations showed that the sylyath and rotifer species formed the dominant populations in the granules.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
50
58
https://www.wwjournal.ir/article_15624_9daf8ed7393fc51022997ae6af4f5172.pdf
Isolation and Identification of Cadmium and Lead Resistant Bacteria and their Bacterial Removal from Wastewater
Sanaz
Abbasi
Former Graduate Student, Department of Soil Science Engineering, Faculty of Agriculture, Shahid Chamran University of Ahvaz
author
Mostafa
Chorom
Assoc. Prof., Department of Soil Science Engineering, Faculty of Agriculture, Shahid Chamran University of Ahvaz
author
Naeime
Enayatizamir
Ass. Prof., Department of Soil Science Engineering, Faculty of Agriculture, Shahid Chamran University of Ahvaz
author
Hossein
Motamedi
Prof., Department of Microbiology, Faculty of Sciences, Shahid Chamran University of Ahvaz
author
text
article
2017
per
Municipal and industrial effluents continually release into the environment heavy metals of a variety of physical and chemical forms and at various concentrations. Biological treatment processes have attracted a growing attention for the removal of heavy metals from these effluents. For the purposes of the present study, bacteria that are relatively resistant to heavy metals, such as cadmium and lead, were isolated from municipal waste and purified. They were then subjected to biochemical tests for identification and their minimum inhibitory concentrations were determined. Bacterial minimum inhibitory concentrations were initially measured in flasks containing 25, 50, 75, 100, 150, 300, 500, and 700 ppm of lead and cadmium before superior bacteria at populations of 108 CFU/ml were evaluated in terms of their ability to remove lead and cadmium at concentrations of 50, 100, 150, and 300 ppm from enriched municipal wastewater. Base on the results, Bacillus laterosporous and Yersinia pseudotuberculosis were identified as the resistant bacteria and the minimum lead and cadmium inhibitory concentrations for these bacteria were determined to be 300 and 500 ppm, respectively. Moreover, Bacillus laterosporous and Yersinia pseudotuberculosis recorded maximum removal efficiencies of around 50.6% and 45.7%, respectively, with wastewater containing 100 mg/l of lead and 36.18% and 21.41% in the case of cadmium from wastewater enriched with 100 mg/l of lead and 150 mg/l of cadmium.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
59
68
https://www.wwjournal.ir/article_15523_649732495000744905208e9ca31b5aa9.pdf
Physical and Chemical Characterization of Fat and Oil Deposits in Mashhad City Sewer Lines and the Solutions Developed
Mahdi
kamali
Lecturer, Institute of Process Engineering, University of Isfahan, and PhD Student of Water and Wastewater Engineering, Graduate Faculty of Environment, Department of Environmental Engineering, University of Tehran
author
Majid
Pirooz
MSc of Chemical Engineering, Department of Chemical Engineering, Faculty of Engineering, University of Isfahan
author
Jalil
Jalilian
BS of Water and Wastewater Engineering, Mashhad Water and Wastewater Company, Mashhad
author
Mohammadali
Asadollahi
Ass. Prof. of Biotechnology, Department of Biotechnology, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan
author
text
article
2017
per
Formation of oil, fat, and grease deposits in sewer pipelines is a major concern as they result in sewage overflow and pose health problems. Analysis of two sample deposits collected from the sewer lines of Imam Reza Street in the city of Mashhad suggested that the chemical reactions promoted by edible oils in the sewer lines lead to the formation of insoluble soap and deposits. Being sticky, the deposits accumulate over time to eventually block the lines. The analysis also showed that the moisture content of the samples ranged between 50‒62%, indicating that water does not play a main role in their formation. The samples were also found to contain 61.78% and 84.35% saturated fatty acids, with palmitic acid being the dominant one. Calcium was the main metal in the samples, which is due to both water hardness and corrosion of the sewer lines. Based on the results obtained, the origin of these deposits, and the relevant protocols for the management of oil and fat wastes, solutions were proposed to prevent deposit formation and sewer line clogging that suit the special cultural and environmental conditions of the city. These proposals are under consideration for implementation in the region.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
69
77
https://www.wwjournal.ir/article_13390_ef7c7928797622a65297d823db29706d.pdf
Efficiency of Worm Reactors in Reducing Sludge Volume in Activated Sludge Systems
Azam
Naderi
Former Graduate Student of Environmental Health Engineering, ،Tehran University of Medical Sceinces, Tehran
author
Mehdi
Farzadkia
Prof. of Enviromental Health Engineering, Faculty of Public Health, Iran University of Medical Sciences, Tehran
author
text
article
2017
per
The activated sludge process is the most widely used on a global scale for the biological treatment of both domestic and industrial effluents. One problem associated with the process, however, is the high volume of sludge produced. Excess sludge treatment and disposal account for up to 60% of the total operating costs of urban wastewater treatment plants due to the stringent environmental regulations on excess sludge disposal. These strict requirements have encouraged a growing interest over the last few years in reducing sludge volumes produced at biological treatment plants and a number of physical, chemical, and mechanical methods have been accordingly developed for this purpose. The proposed methods are disadvantaged due to their rather high investment and operation costs. An alternative technology that avoids many of these limitations is the worm reactor. In this study, the characteristics of this technology are investigated while the related literature is reviewed to derive the optimal conditions for the operation of this process in different situations.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
78
86
https://www.wwjournal.ir/article_13147_1dcdf5b73a30884982317b77dfdd6485.pdf
GIS-based Assessment of Arsenic Contamination of Water Supplies in Rural Areas of Rivash Town: Comparisons with National and WHO Standards
Hossein
Alidadi
Assoc. Prof., Department of Environmental Health, and Research Staff Member of Health Sciences Research Center, Faculty of Health, Mashhad University of Medical Sceinces, Mashhad, Iran
author
Azam
Ramezani
MSc Student of Environmental Health Engineering, and Staff Member of Research Committee, Mashhad University of Medical Sceinces, Mashhad, Iran
author
Batool
Moheb Rad
PhD Student of Environmental Health, and Instructor of Health Faculty Mashhad University of Medical Sciences, Mashhad, Iran
author
Ali Akbar
Dehghan
PhD Student of Environmental Health, and Instructor of Health Faculty Mashhad University of Medical Sciences, Mashhad, Iran
author
Habibollah
Esmaeili
Assoc. Prof. of Biostatistices, Faculty of Public Health, Mashhad University of Medical Sciences, Mashhad, Iran
author
Shahrbanoo
Raffe
MSc Student of Environmental Health and Member of Public Health, Mashhad University of Medical Sceinces, Mashhad, Iran
author
Maryam
Dowlatabadi
MSc Student of Environmental Health and Member of Public Health, Mashhad University of Medical Sceinces, Mashhad, Iran
author
Maryam
Paydar
BS in Environmental Health Engineering, and Instructor of Health Faculty, Mashhad University of Medical Sceinces, Mashhad, Iran
author
text
article
2017
per
Arsenic is one of the most hazardous elements in drinking water. Water contaminated with arsenic causes a variety of diseases in humans including cancer. The present study was conducted to survey Arsenic concentration in rural water resources in Rivash Twon, Kashmar, Iran. For the purposes of this cross-sectional study, 60 samples were collected from 10 underground drinking water supplies during the period from April to June, 2013. Samplings and sample preservation were performed according to standard methods. Measurements were performed via the VGA method using atomic absorption. Such water quality parameters as pH, TDS, EC, residual chlorine, and temperaturte were also measured to determine any relationships likely to exist between As concentration and the parameters measured. As levels were then compared with national and international standards. It was found that the average values of As concentration at the stations A, B, C, D, E, F, G, H, I, and J were 1.53±1.03, 1.30±1.07, 10.55±3.83, 11.21±5.01, 10.57±3.68, 2.34±0.73, 3.22±0.58, 9.89±3.57, 10.48±5.07, and 2.23±0.53 µg/L-1, respectively. As concentrations at five stations were found to be higher than the values recommended in WHO guidelines; the remaining stations revealed values below the national standard. While the differences between As level and the national standard were statistically significant (p<0.001), those between As level and WHO standard were significant (p<0.001) in 50% of the stations studied. Except in the case of pH, no significant relationships were detected between As level and any of the TDS, EC, temperature, salinity, or residual chlorine values. From the results of this study, it may be suggested that it is essential to plan for replacing safe drinking water supplies for the current polluted ones with high AS levels in the district. Controlling the present water supplies on a regular basis is also highly recommended.
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
87
91
https://www.wwjournal.ir/article_15745_ac5988dda580955c7e91169da0fc1173.pdf
English Abstracts
text
article
2017
per
Journal of Water and Wastewater; Ab va Fazilab ( in persian )
Water and Wastewater Consulting Engineers
1024-5936
27
v.
6
no.
2017
https://www.wwjournal.ir/article_34113_3b4533c385afe9165e3fae3f5dd35c64.pdf